Carrier 58pav Inducer replacement 31 Pressure Fault Code ...
Replacing inducer motor on a Carrier 58PAV, Bryant 383KAV or similar Payne furnace. This inducer assembly was in many furnaces from early 1990's through about 2010. Category ... View Video
FA4A DIRECT EXPANSION FB4A FAN COIL FC4B
High-impact thermoplastic condensate pan • Primary and secondary drain connections with brass inserts • Multipoise design for maximum versatility • Field-installed heater packages from 3–30 kw (fused, circuit breaker, or non-fused) • Control board with built-in, replaceable 5-amp blade-type auto fuse • Cooling controls • Time ... View Document
FA4B Product FB4B Data Direct Expansion Fan Coil
2. To avoid potential for condensate blowing out of drain pan prior to making drain trap: —Return static pressure must be less than 0.4 in. wc —Horizontal applications of 048-070 sizes must have supply static greater than 0.20 in.wc Airflow outside max ARI airflow of 450 cfm/ton on 018-154 sizes Airflow above 400 cfm/ton on 060-070 sizes. ... Read Content
EVAPORATOR COIL INSTALLATION INSTRUCTIONS
The evaporator coil is provided with ³⁄₄ in. NPT condensate drain connections. Make sure unit is level with the drain opening so that the drain pan will empty completely without water standing in the pan. 1. Connect primary drain line connection to the drain pan (large hole). 2. Connect secondary drain line connection to the drain pan ... View Doc
Commercial Refrigeration Condensate Evaporator Pans
Condensate Evaporator Pans For condensate applications where no drain is available, choose the large capacity pan that fits your application. SUPCO commercial refrigeration condensate evaporator pans are made from top quality Cross Reference Replacement Parts ... Retrieve Full Source
Product WEATHERMASTER® 48HJ004-028 Data Single-Package ...
Sate drain pan (size 004-014) permits either an external horizontal side condensate drain (outside the roof curb) or an internal vertical bottom drain (inside the roof curb). Both options require an external, field-supplied P-trap. Standard 2-in. throwaway filters are easily accessed through a remov-able panel located above the air intake hood. ... Read Here
Condensate Drain Pans - SupplyHouse.com
A code specified secondary safety pan for interior installed air handlers. Will not rust, corrode, or collapse when filled with water. All pans are furnished with a 3/4” PVC outlet for drain line. For new construction, place pan on 3/4” plywood for greater support. 570-791n 7/20/6 11:50 AM Page 1 ... Fetch Content
HORIZONTAL 2-WAY CASED EVAPORATOR COIL INSTALLATION INSTRUCTIONS
Regardless of the condensate drain design used, it is the installer’s responsibility to ensure the condensate drain system is of sufficient design to ensure proper condensate removal from the coil drain pan. ... Access This Document
Product Data - Aire Acondicionado Y Climas Sa De Cv
Pitched drain pan can be adjusted for a right--hand or left--hand connection to provide positive drainage and prevent standing condensate. Accessory economizer can provide ventilation air to improve indoor air quality. When used with CO2 sensors, the economizer admits fresh outdoor air to replace stale, recirculated indoor air. ... Fetch Full Source
BEVERAGE-AIR - Parts Town
48 all but sf34 condensate pan assy.08b30-026c 48 sf34 condensate pan assy. 08b30-027c 49 dw64/49 **ref. charge r134a 6.75 ounces 49 dw79/94 **ref. charge r134a 16.5 ounces 49 sf34 **ref. charge r134a 7.5 ounces item model description part number 50 sf34 (florescant) interior light assy. 28b32-031c 50 dw49 (florescant) interior light assy ... Retrieve Document
INSTALLATION INSTRUCTIONS Evaporator Coils - AirEase
Result in property damage, a secondary drain pan must be provided by the installer. The secondary drain pan must be connected to a drainage system separate from the primary condensate drain. CAUTION Be sure that the coil is installed level or with a slight slope toward the drain connection to ensure proper condensate diisposal. ... Fetch Document
Product Catalog - Trane
Condensate Overflow Switch A condensate overflow switch is available to shut the unit down in the event that the condensate drain line becomes clogged. This option protects the unit from water overflowing from the drain pan and entering the base of the units. 1 Refer to “Model Number Description,” p. 15 for option availability. ... View Document
Replacement Parts - Carrier Enterprise
7 PSRKIT05 Condensate Drain Assembly 8 PSRKIT06 Boiler Piping - Return Assembly 9 PSRKIT08 Boiler Piping - Supply Long Assembly 10 PSRKIT07 Boiler Piping - Supply Short Assembly 11 HMCIR01 Circulator 12 PTRKIT119 Polyproplylene Condensate Pan ... Access Full Source
Totaline Condensate Drip Pan Cleaner
Totaline® Condensate Drip Pan Cleaner Totaline® Condensate Drip Pan Cleaner is a controlled release, water activated product that easily fits into most air conditioners, refrigerator drip pans and humidifier water tanks. ... Access Content
Cooling Coil And Drain Pan Requirements For Air Handling Units
Article are to highlight proper handling of condensate drain from chilled water cooling coil, improve coil performance, reduce moisture carryover, minimize potential of mold growth, reduce potential for corrosion, premature replacement of downstream components and facilitate coil maintenance and replacement. ... Doc Viewer
AC Evaporator Coil Cleaning Water In pan - YouTube
Air Conditioner Evaporator coil cleaning, due to debris in the drain line that caused pan underneath unit to fill out with water. Coil was relatively clean but rust pieces were in the evaporator's ... View Video
COMMERCIAL GRADE CONDENSATE PUMPS - Ksminc.net
UL Listed - 30 Foot Head - 1 Gal. Reservoir - HIGH TEMPERATURE (212 Degrees F) - Built in Check Valve ... View This Document
Condensate Pump replacement - YouTube
Little Giant 554401 VCMA-15UL 1/50 horsepower 115 volts VCMA Series Automatic Condensate Removal Pump http://amzn.to/2rEHClS. ... View Video
HVAC - Wikipedia
This moisture is collected at the bottom of the evaporator in a pan and removed by piping to a central drain or onto the ground outside. A dehumidifier is an air-conditioner-like device that controls the humidity of a room or building. ... Read Article
Installation Instructions February 2014 Evaporator Coil
Remove the horizontal drain pan, and re-install it to the opposite side of the coil (Note: horizontal drain pan must have drain plugs tightly closed in the rear of the unit). Remove the top plate. Remove the water diverter, and re-install it to the op-posite slab (Note: If water diverter is attached by ... Retrieve Content
Evaporator Coil Installation Instructions - Denver Winair
Pan. See Figure 2. If the coil is located in or above a living space where damage may result from condensate overflow, a separate ¾” drain must be provided from the secondary drain connection. Run this drain to a place in compliance with local installation codes where it will be noticed when unit is operational. ... Read Full Source
Installation Operation Maintenance - Trane
Use the coil or drain pan as a reference since the coil is pitched and the drain pan is sloped to provide proper drainage. o 4. Condensate Line A continuous pitch of 1 inch per 10 feet of condensate line run is necessary for adequate condensate drainage. o 5. Wall and Ceiling Openings Units with ceiling access panels only: ... View Doc
No comments:
Post a Comment